Archive Post

England’s trash generating Danish heat

Power in Denmark is increasingly being generated in plants burning waste imported from England. The…

kleine Verbrennungsanlage

Verbrennungsanlagen Entsorgungssystem für biologische Abfälle (Verbrennungsanlage) Die Verbrennungsanlage muss die folgenden Spezifikationen erfüllen: - Verbrennungsleistung…

Pyrolysis Deemed a Viable Alternative to Incinceration

Researchers at the University of York have concluded that PyroPure (UK) technology has the potential…

Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS

Supply, Installation and Commissioning of DIESEL FIRED INCINERATORSMedical Waste Incinerator, 100 to 120 Kg/hrApplication   For incineration, general and pathologicalCapacity    100 C 120 kg/h burn rateType Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unitOperating time                Minimum 8 hours dailyOperating temperature     From 850 0C to 1200 0C, Automatic controlledResidual Ash                    5 to 10%Construction Constructed from heavy duty mild or aluminized  steelOr equal and approved equivalent Insulation material            Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickworkInternal Construction        Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory materialCharging Door                   Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges.Door Lock                          Automatic, Electric typeAsh removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamberGratings    ProvidedLoading…

Incinerator Furnaces for Pet Cremation

Basic Info. Model NO.:incinerator manufacturers in middle east Export Markets:Global Product Description Key Features:  *…

Norfolk incinerator bill wrangle could continue until after Christmas

Norfolk County Council voted by 48 votes to 30 to terminate the contract for the…

N.D. could receive Ebola waste from Calif.

FARGO, N.D. — California health officials have given notice that North Dakota is one of…

INCINERATOR SPECIFICATION Capacity UPTO 20 kg/hr

Size:  940 x860x2700 mmMaterial:  STAINLESS STEEL STACK, REFRACTORY CONCRETE LINING SPECIAL INSULATION MATERIALWith burner:  15 C 20 KWTemperature:   PRIMARY CHAMBER = 800°C AND SECONDARY CHAMBER = 850 – 1200° CSufficient heat generation for secure and complete combustion 600-800 °C in the first chamber and >1000 °C in the second chamberEasy transportation on standard EURO-pallets Constructed in a modular fashion  easy on-site movement and assembly with a minimum of equipment and technical skills;For the destruction of problematic waste like sharps, amputates and body parts, wet or moist matter; Off-gas quality: moderate smoke emissions during one quarter of the total incineration time; no visible emission during three quarters. AS PER INTERNATIONAL STANDARDS The remaining ash approximately 5-10% in weight and below 1% in volume of the original waste AS PER INTERNATIONAL STANDARDS Chimney height at least 5 m above the incinerator 5m ABOVE FROM THE GROUNDTemperature resistance of the lining  at least 1,200 °C

Portable Incinerator

Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Nanjing Clover Medical Technology Co., Ltd..…
Auto Air Filters